Menu Buttons Click for the Home Page Click Information on Hansatech Instruments Click for the Products Section Click for the Support Section Click for Contact Details

You are in: Products > Oxygen Measurement > Light Sources > LS2

Hansatech Instruments LS2 High Intensity White Light Source

LS2 High Intensity White Light Source

  High intensity 100W tungsten halogen light source (50W option available).
  Max. intensity up to 1800 µmol m-2 s-1 in DW1, DW1/AD and LD1/2 electrode chambers.
  Max. intensity up to 8000 µmol m-2 s-1 in DW2/2, DW3 & LD2/3 electrode chambers using LS2/FO and A8 accessories.
  Integral optics provide minimum intensity variation across beam and little divergence from parallel.
  Integral infrared reducing Hot-Mirror filter.
  Mains powered stabilised power supply.
  Mounting slots allowing addition of filters for intensity attenuation or spectral modification.

Overview

The LS2 light source is a high intensity (100W) tungsten halogen light source which is powered from a stabilised power supply. The lamp housing contains a cooling fan, infrared reducing “Hot-Mirror” and optics to provide light with minimum variation of intensity across the beam and little divergence from parallel. 2 slots are provided to accept 50mm square optical filters or a manual shutter plate. A range of light intensity steps may be achieved by adding permutations of the 4 A5 neutral density filters supplied (0.1,0.3,0.6 and 1.0 O.D.) to attenuate the light intensity. Maximum sample illumination intensities vary depending on the type of electrode chamber in use. The table below shows the maximum achievable sample illumination intensities for each electrode chamber.
Chamber Max. Intensity
DW1 1800 µmols m-2 s-1. LS2 mounted horizontally to chamber
DW1/AD 1800 µmols m-2 s-1. LS2 mounted horizontally to chamber
DW2/2 8000 µmols m-2 s-1. Requires LS2/FO and A8 accessories to interface with DW2/2 optical port
DW3 1800 µmols m-2 s-1. LS2 mounted on to locating ring of larger optical window
8000 µmols m-2 s-1. Requires LS2/FO and A8 accessories and 16mm dia. reducing adapter (supplied with DW3) inserted into smaller optical port
LD1/2 1800 µmols m-2 s-1. LS2 mounted horizontally to chamber
LD2/3 1800 µmols m-2 s-1. LS2 mounted horizontally to chamber
8000 µmols m-2 s-1. Requires LS2/FO and A8 accessories inserted into 16mm dia. optical port

Optional Accessories

  LS2/FO Fibre Optic Adapter
  A8 Fibre Optic Cable
  A4 - Additional optical filter holder for LS2 white light source
  A5 - Set of 4 50mm square neutral density filters for LS2 white light source
 

Click to go to the Top of this Page
 
Quick Links
Hansatech Instruments Product Literature Hansatech Instruments Ltd. Worldwide Distributor Network Hansatech Instruments Customer Support Article on Electrode Disc Maintenance
 

Copyright© Hansatech Instruments Ltd 2007. All rights reserved. Terms & Conditions Legal Disclaimer Sitemap

Valid XHTML 1.0 Transitional     Valid CSS!