Which System?

To discover which of our Complete Oxygen Electrode Systems is appropriate for your requirements, please see the flowchart below. Once you have established which system best fits your need, please click the link below the system name to visit the relevant product. Alternatively, please click here to view the full range of complete electrode systems.

If you still are unable to find what you are looking for, please contact Hansatech Instruments for further advice.

Sample Media
Sample Media
Gas-Phase Sample
Gas-Phase Sample
Liquid-Phase Sample
Liquid-Phase Sample
Required system control
Required system control
Manual
Manual
Automated
Automated
Required system control
Required system control
Manual
Manual
Automated
Automated
Configuration and operation of the system is entirely manual. Recorded signal is displayed on an LCD screen with option to record data externally via analogue output.
[Not supported by viewer]
Configuration and operation of the system is Windows PC based. Recorded signals are plotted in custom software as real-time chart recorder emulation.
[Not supported by viewer]
Configuration and operation of the system is entirely manual. Recorded signal is displayed on an LCD screen with option to record data externally via analogue output.
[Not supported by viewer]
Configuration and operation of the system is Windows PC based. Recorded signals are plotted in custom software as real-time chart recorder emulation.
[Not supported by viewer]
[Not supported by viewer]
Main intended use
Main intended use
Temperature control
Temperature control
No
No
Yes
Yes
No
No
Yes
Yes
Required sample volume
Required sample volume
Automated light source control?
Automated light source control?
Automated light source control?
Automated light source control?
Oxygen Electrode Measurement
<span>Oxygen Electrode Measurement</span>
[Not supported by viewer]
Integrated

Sample temperature control is provided by a Peltier Element within the electrode chamber itself.
[Not supported by viewer]
External

Sample temperature control is provided by an external thermoregulated circulating water bath.
[Not supported by viewer]
Teaching

Whilst having sufficient functionality and signal quality to provide research grade data, the main function of the system is for teaching purposes.
[Not supported by viewer]
Research

Although suitable for teaching, the signal quality and flexibility of the system is more suited to research grade analysis applications.
[Not supported by viewer]
0.2ml - 2.5ml

Suitable for most liquid-phase samples including chloroplasts and micro-algae photosynthesis assays.
[Not supported by viewer]
2ml - 20ml

Large volume chmaber specifically designed for larger sample volumes or samples laminar in nature.
[Not supported by viewer]
Chloroview 1
Click here to view
[Not supported by viewer]
[Not supported by viewer][Not supported by viewer][Not supported by viewer][Not supported by viewer]
Chlorolab 2+
Click here to view
[Not supported by viewer]
Chlorolab 3+
Click here to view
[Not supported by viewer]